Oxygen compressor specification Compressor entrance Conditions Compressor exit Conditions Flow Below 4 cases to be quoted.Oxygen concentration Nor:90% Max:95% Min:80%Pressure 20-50kPa Nor:3, 800kPa Max:5, 500kPa Temperature Normal temperature Compressor entrance flux Conditions CASE1 Nor: 100Nm3/h, Max:120Nm3/h CASE2 Nor: 200Nm3/h, Max:240Nm3/h CASE3 Nor: 400Nm3/h, Max:480Nm3/h CASE4 Nor: 40Nm3/h, Max:50Nm3/h Utility conditions Power supply 460V 3phi 60Hz (less than 250kW) 4160V 3phi 60Hz (250kW or more) Control source AC 100V Instrumentation air pressure 0.50MPa Water pressure for industry 0.30MPa Industrial water temperature 25 degrees C (Please Specify the amount of each to use in estimated specifications.) Installation design condition Installation features Outdoors (it is an installation schedule to a building with a roof (out of the scope).) Outside temperature 10-40 degrees C Humidity 30 - 100% Noise value Less than (opportunity side 1m) 85dB Calorific value Write in estimated specifications clearly. Bolt Please select by venderMotor IP54 DCS 4-20 mA, DC24V point of contact (connection out of the scope)(4 point : operation , pressure , alarm , spare)Standard Be based on ASTM and JIS. oxigen, compressor, o2 O2 compressor