Entered incorrect captcha
div header bar

Quotation Offer

  • Sourcing Country:IndiaIndia
  • Required Quantity: Ask From Buyer
  • Posted Date:30 Mar 2024
  • Expiry Date:02 Jun 2024
  • Buyer Name: satish
  • Usage:
    Ask From Buyer
  • Buying Frequency: One Time
  • Email:
    s****h************m
  • Approx Order Value:
    Ask From Buyer
  • Quotations Received: 11 Quotes
  • Contact Number:
    9****4***5
  • FOB Price:
    Ask From Buyer
  • Time Left: 35 Days
  • Shipping Terms:
    Ask From Buyer
  • Payment Terms: T/T, LC, D/P, PayPal, Western Union
  • Preferred Supplier Country:ChinaChina

RFQ Description

Details of Major items to be procure for Jabalpur (M.P. State) feeder separation work.S/No. Description of itemUnitTotal qty from Lot 1 to 5 and 9, 10.1Bus bar structure for additional bay on 11 KV side double welded galvanized RS Joist175x85 mm 8.0 M long (328 Kg) No.894Total wt. required RSJSINGLE.894 x 328 ***2 (i)DC cross arm galvanized channel 100x50x6mm 4.8 Mcentre (49.92 Kg) for bus bar. No.2682Total wt. required 49.92 x 2682 ***(ii)DC cross arm 4 feet centre galvanized channel 100x50x6 mm 2.2 M (53.4 kg) (Drg. No. DISCOM/EZ/20)Set.29334Total wt. required 53.4 x 8968 ***(iii)DC cross arm 8ft centre galvanised channel 100x50x6 mm 2.8 M (56.3 Kg)Set8969Total wt. required 56.3 x 29334 ***43PCC pole 140 Kg 8.0 M longNo.***411 KV disc insulatorNo.***511 KV strain hardware suitable for ACSR conductor 200 ***** Panther.No.***611 KV pin insulatorNo.***711 KV GS pinNo.***811 KV LA, station Type.No.***11KV isolator (600 amp)Set44710ACSR conductor 200 sq. mm.PantherKM4.4711AAA conductor 55 sq. ***** with 3% sag.Km.40022.71211KV VCB (Outdoor)No.67113CTs 11KV - 200-100/5No.***Control Relay Panel 11KV No.15CT/PT unit 11KVNo.67116HT-TVM Meter -110V/5ANo.67117 (i)PVC cable unarmoured, 25 sq. mm. 3.5 core connecting LT bushing to energy meter.Mtr.25098(ii)1100 Volts Grade AB XLPEcable 3x50 sq. mm. + 1x16***** +1x 35 sq mm including3% sagKM6852.59(iii)PVC cable, 1100 Volts gradetwin core, unarmoured, 6 sq.mm. with 3% sag.Km.645.81(iv)Copper Control cable 4 core 2.5 sq. mm (unarmoured)Mtr.50325(vi)Copper Control cable 8 core 2.5 sq. mm (unarmoured)Mtr.***8Galvanized Nuts & bolts with washer.Kg.*** power project, insulators, pvc cables, acsr conductors, isolators, pcc poles etc. Insulators,D.O. Fuse units,Bus Bar Structures,Galvanized Channels, PCC Poles,Disc Insulators,pin insulators,11 KV GS pin,11 KV LA Station type, 11KV Isolator(600 amp), ACSR conductor 200 sqmm panther, AAA conductor 55 sqmm rabbit with 3 % sag, 11 kv VCB

Send Your Quotation To This Buyer

Scroll
ExportHub Virtual Expo
Scroll to Top

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.