Entered incorrect captcha
div header bar

Laboratory Equipments

  • Sourcing Country:KenyaKenya
  • Required Quantity: Ask From Buyer
  • Posted Date:15 Apr 2024
  • Expiry Date:14 Jun 2024
  • Buyer Name: wahome wanjohi
  • Usage:
    Ask From Buyer
  • Buying Frequency: One Time
  • Email:
    w****h************e
  • Approx Order Value:
    Ask From Buyer
  • Quotations Received: 4 Quotes
  • Contact Number:
    2****2*******0
  • FOB Price:
    Ask From Buyer
  • Time Left: 46 Days
  • Shipping Terms:
    Ask From Buyer
  • Payment Terms: T/T, LC, D/P, PayPal, Western Union
  • Preferred Supplier Country:ChinaChina

RFQ Description

ITEM 1: GAS SAMPLING FLASKSThe flasks are for collecting gas samples from geothermal wellsTo be made of borosilicate glassTo withstand temperatures of up to 300 deg C To withstand pressures of up to 10 bars (g)To have two (2) open ends fitted with air-tight screw-able teflon stopcocks. Volume: 300- 400 mlThe flasks shall be subjected to physical testing under the above conditions before delivery is accepted.Manufacturers Authorization Must be provided. Brochure and operation manual Must be provided.ITEM 2:TITROPROCESSOR-Measuring range-pH value pH 0.00 to 14.00-Voltage U-2000.|+2000 Mv-Temperature Temp -20 to + 200Should come complete with-two dosimats-Three exchange units of various sizes i.e.10 ML, 50 ML, and 100 ML-Thermal printer-Voltage 240 volts-Frequency 50 HzITEM 3: THERMOCOUPLESThe equipment is used for measuring temperatures of geothermal fluids during geothermal explorations. : With Calibration certificate, temperature range 0-300 deg C. Penetration probe and general purpose probe;Penetration Probeequal or more than 90 cm . :Carrying case, spare batteries :General purpose probe 0-100 deg CITEM 4: STANDARD TESTING SIEVES FOR SOIL PARTICLE DISTRIBUTION TESTSThis equipment is used for carrying out particle size testing of different materials e.g. soils distribution. :Should have individual serial numbers for traceability :Should come in 3, 4, 5, 6, 8, 10 and 12 sizes. :Should rigid rolled edges and extended bottom skirts to ensure good fit between frames, pans and separators and same diameter :Should have sieve number, micron size, and nominal opening in millimeters and inchesITEM 5: PORTABLE DIFFUSE FLUX METER. CARBON DIOXIDE, METHANE AND HYDROGEN SULFIDE.With the following specifications:A West systems Flux meters:Backpack-like support vest:Carrying case for transport and storage:2 batteries NiMH 14.4 Volts 4.5A/h and 1NiMH battery charger. measuring, test, and analysis, equipments test and reseach equipments

Send Your Quotation To This Buyer

Scroll
ExportHub Virtual Expo
Scroll to Top

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.