HYPOCHLORITE GENERATOR PACKAGE UNIT

  • Sourcing Country:Saudi ArabiaSaudi Arabia
  • Required Quantity: Ask From Buyer
  • Posted Date:06 Apr 2024
  • Expiry Date:28 May 2024
  • Buyer Name: Subrahmannyan
  • Usage:
    Ask From Buyer
  • Buying Frequency: One Time
  • Email:
    s****h****************m
  • Approx Order Value:
    Ask From Buyer
  • Quotations Received: 1 Quotes
  • Contact Number:
    9****5*******2
  • FOB Price:
    Ask From Buyer
  • Time Left: 30 Days
  • Shipping Terms:
    Ask From Buyer
  • Payment Terms: T/T, LC, D/P, PayPal, Western Union
  • Preferred Supplier Country:ChinaChina

RFQ Description

Skid mounted sodium Hypochlorite Generation Package (with 100% standby) The system shall be sized to continuously dose active chlorine into seawater flow of 400 gpm from firewater pumps at 2 ppm concentration. Skid Inlet Water Pressure: 105 to 150 PSIG Design Temperature: 120 F The system shall consist of complete electrolytic sodium hypochlorite generators from seawater on a once through basis. Each unit shall have hypochlorite production turndown capability from 10% to 100% of specified design capacity Due to limited space, system shall be of compact construction. (Approx. 2m x 5m) The system shall include: - Electrolytic cell assembly. - Transformer/ Rectifier Unit, dry type transformer, air cooled, thyristor controlled rectifier, suitable for 480VAC/3PH/60Hz power feed. System shall be capable of diluting Hydrogen generated to safe levels and venting it to a safe location. - Main Control Panel; PLC based; hosed in 316 stainless steel IP56 (NEMA 4X) enclosure, designed to provide necessary pushbuttons, run lights, alarms, indicators, relays and control circuitry as required for safe operation of the system; including HMI touch screen interface, with both RS-485 and Modbus TCP/IP interface network cards for communication with DCS. - All required process piping, valves, pressure regulators, safety valves, etc. Materials shall be suitable for offshore application, preferably CPVC SCH. 80. - Shall be supplied with booster pumps and flow regulators for the inlet seawater when required. - Inlet strainers shall be supplied. One automatic backwash and one manual. (D-070/071). - Supplied with pumps to inject the hypochlorite into a firewater stream with a pressure of 1137 kPa (165 psig). - Assembly of the units on structural steel skids, with APCS-1D (SAES-H-004) coating suitable for corrosive, hot, humid, salt laden offshore environment, lifting lug and grounding lugs. - hypochlorite generator Raised tiles, Accoustic Ceiling

Send Your Quotation To This Buyer

Scroll
ExportHub Virtual Expo
Scroll to Top

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.